FEC-11CP Series
Industrial 10/100Base-TX Ethernet over Coaxial Converter with PoE & PoC
3 V1.3
Coaxial Link Data Rate
There is a switch beside the Video connector. It can be used to control the distance of the coaxial link. If longer
distance is selected (switch position in L), the transmission distance can be reached up to 500m.
Position Distance
Data Rate
Downlink
(TX to RX)
Uplink
(RX to TX)
NORMAL
300 m 36 Mbps 11 Mbps
LONG
500 m 21 Mbps 3 Mbps
LEDs
The LED indicators give you instant feedback on status of the EoC Transmitter & Receiver:
LEDs Colour State Indication
PWR Green
Steady Power on, PWR
stands for POWER
Off Power off
Coax
Link Green
Steady The transmitter and receiver communicate and lock with each others.
Off The transmitter and receiver do not communicate or the coaxial cable is disconnected.
ACT Green
Flashing
Data transfer within the coaxial cable. The brightness depends on the data rate. The lower
the data rate, the dimmer is the LED.
Off No data transfer within the coaxial cable
PoC (RX) Green
Flashing
Un-connected: Flash once, OFF five times
TX powed by 48V adaptor: flash twice, OFF four times
Over current : flash thrice , OFF thrice
Checking : flashing
ON Power over Coax
Off RX is power under 48V
PoE (TX) Green
Steady Power is applied to the Power Device (PD)
Off A non-PoE device is connected or no Ethernet connection.
Ethernet
Link/Act Green
Steady A valid Ethernet connection established
Flashing Transmitting or receiving Ethernet data, Act stands for ACTIVITY
Off Neither valid Ethernet connection established nor transmitting/receiving Ethernet data
Spd Yellow
Steady Ethernet Connection transferring at 100Mbps
Off Ethernet Connection transferring at 10Mbps
Manual Earth Green manual is available on our website www.neotechcomm.com.tw